Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
rw:comp:a2000:power [2022/06/27 14:52] super |
rw:comp:a2000:power [2022/10/26 17:29] (current) super |
||
---|---|---|---|
Line 1: | Line 1: | ||
=====Amiga 2000 Power Notes===== | =====Amiga 2000 Power Notes===== | ||
- | **Power Supply** | + | ====Power Supply==== |
* Molex 2139 KK 3.96MM 14pin | * Molex 2139 KK 3.96MM 14pin | ||
Line 12: | Line 12: | ||
|3|+5V|yellow|| | |3|+5V|yellow|| | ||
|4|+5V|yellow|| | |4|+5V|yellow|| | ||
- | |5|GND1|blue|total +12V load is 8A| | + | |5|GND1|blue|| |
|6|GND2|blue|| | |6|GND2|blue|| | ||
|7|GND3|blue|| | |7|GND3|blue|| | ||
Line 36: | Line 36: | ||
* is this just their hardware adapter or all atx adapters? | * is this just their hardware adapter or all atx adapters? | ||
- | **ATX PC Power Supply** | + | ====Replacement |
+ | Sadly, you can't just substitute any ATX in for the A2000, see below. | ||
+ | |||
+ | **Meanwell** | ||
+ | |||
+ | Meanwell has become a standard for replacing power supplies for the 8 and 16 bit lines. | ||
+ | |||
+ | * MPQ-200B | ||
+ | * medical rated, high quality + high cost | ||
+ | * rated for 200W | ||
+ | * output | ||
+ | * +5V at 15A (vs 20.5A) | ||
+ | * +12V at 7A (vs 8A) | ||
+ | * -5V at 2A (vs .3A) | ||
+ | * -12V at 2A (vs .3A) | ||
+ | * RQ-125B | ||
+ | * only 125W! | ||
+ | * output | ||
+ | * +5V at 11A (vs 20.5A) | ||
+ | * +12V at 4.5A (vs 8A) | ||
+ | * -5V at 1A (vs .3A) | ||
+ | * -12V at .5A (vs .3A) | ||
+ | |||
+ | ---- | ||
+ | |||
+ | ====ATX PC Power Supply==== | ||
+ | |||
+ | Here's the standard PC power supply to compare to Amiga' | ||
^Pin^Name^Color^Description^ | ^Pin^Name^Color^Description^ | ||
Line 64: | Line 91: | ||
|23|+5V|Red|+5 VDC| | |23|+5V|Red|+5 VDC| | ||
|24|COM|Black|Ground| | |24|COM|Black|Ground| | ||
- | |||
* /PSON activated by pressing and releasing the power button while the power supply is in standby mode. Activating /PSON connects the power supply' | * /PSON activated by pressing and releasing the power button while the power supply is in standby mode. Activating /PSON connects the power supply' | ||
* 18 AWG is recommended for all wires except pin 11, which should be 22 AWG. For 300W configurations 16 AWG is recommended. | * 18 AWG is recommended for all wires except pin 11, which should be 22 AWG. For 300W configurations 16 AWG is recommended. | ||
- | |||
- | **Meanwell** | ||
- | * MPQ-200B | ||
- | * medical rated, high quality + high cost | ||
- | * rated for 200W | ||
- | * output | ||
- | * +5V at 15A (vs 20.5A) | ||
- | * +12V at 7A (vs 8A) | ||
- | * -5V at 2A (vs .3A) | ||
- | * -12V at 2A (vs .3A) | ||
- | * RQ-125B | ||
- | * only 125W! | ||
- | * output | ||
- | * +5V at 11A (vs 20.5A) | ||
- | * +12V at 4.5A (vs 8A) | ||
- | * -5V at 1A (vs .3A) | ||
- | * -12V at .5A (vs .3A) | ||
Last modified: le 2022/06/27 14:52